<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-30 03-01-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 47 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 2.8 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
16 kHz 38 kHz 18837 0,1805
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,97 dBr -0,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 3:01, 30.04.2025
RT
"Ceske pisnicky ktere si zazpivate "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 38 kHz MIN: 16 kHz % above 77 kHz: 0,1805 Acquired: 2025/04/30 3:01:13 Total samples: 18837 Equivalent time: 0:15:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800 1000
FM Scope MAX: -0,7 dBr MIN: -1,4 dBr AVE: -0,97 dBr % above 0,2 dBr: 0,0 Last value: -0,9 dBr (2025/04/30 3:01:13) 02:48 02:50 02:52 02:54 02:56 02:58 03:00 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality